Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 往年索引

鐵心電抗器設計中氣隙取值的分析

來源:電工電氣發(fā)布時間:2016-08-01 14:01 瀏覽次數:8
鐵心電抗器設計中氣隙取值的分析
 
吳紅波
(北京電力設備總廠有限公司, 北京 102401)
 
摘 要:基于產品計算和制造實際經驗, 介紹了一種鐵心電抗器設計中氣隙數量的取值方法,通過氣隙數量的計算分析和對鐵餅工藝偏差、氣隙排布等情況的分析,得到相對合理的氣隙取值。結果表明該取值方法有助于提高鐵心電抗器電抗值的一次性合格率和提高生產效率。
關鍵詞:鐵心電抗器;設計;氣隙;取值分析
中圖分類號:TM471     文獻標識碼:B     文章編號:1007-3175(2016)07-0016-03
 
Analysis of Air Gap Value in Iron Core Reactor Design
 
WU Hong-bo
(Beijing Power Equipment Group Co., Ltd, Beijing 102401, China)
 
    Abstract: Based on product calculation and practical experience of manufacture, this paper introduced a kind of air gap valuing method in iron core reactor design. After calculation analysis of air gap value, discus technology bias and gas configuration, this paper obtained the relative reasonable air gap value. The results show that this method helps to improve the disposable pass rates of reactance value and production efficiency.
    Key words: iron core reactor; design; air gap; value analysis
 
參考文獻
[1] 劉傳彝. 電力變壓器設計計算方法[M]. 沈陽:遼寧科學技術出版社,2002.
[2] GB/T 1094.6—2011電力變壓器 第6 部分 電抗器[S].
[3] 鞠非. 無功補償電容器的串聯(lián)電抗器的選擇[J].電力電容器,2006,27(6):4-7.
[4] 周振華. 干式帶氣隙鐵心電抗器電磁設計方法研究[D]. 西安:西安交通大學,2011.
[5] 趙亮,張建軍,梁棟. 干式帶氣隙鐵心電抗器電感計算方法[J]. 高壓電器,2012,48(6):61-63.